Entire Safe’s SP-series is the safest earthquake protection solution for information and communication assets.
We will continue to innovate and offer our maximum efforts to continuously protect you against not only earthquakes but all natural disasters.
In case of earthquake
![]() | ![]() |
Rack Movement or Conduction | Flooring Collapse |
Without the seismic floor, in the event of an earthquake, racks move and facilitate conduction in response to a load imbalance caused by seismic motion; the floor fails to compensate for the difference in amplitude between the lower and upper supports that carry the high loads.
![]() | ![]() |
Seismic isolation device maintains stability even during seismic motion | The seismic isolation access floor maintains its load balance even during vibrations |
When applied to a rack-only seismic isolation device or to the seismic isolation access floor, our seismic isolation technology transmits energy to the top and isolates it to ensure the stability of both the seismic isolation device and the rack resting on the seismic isolation flooring.
Entire Safe’s SP-series is the safest earthquake protection solution for information and communication assets.
We will continue to innovate and offer our maximum efforts to continuously protect you against not only earthquakes but all natural disasters.
![]() | ![]() |
Rack Movement or Conduction | Flooring Collapse |
Without the seismic floor, in the event of an earthquake, racks move and facilitate conduction in response to a load imbalance caused by seismic motion; the floor fails to compensate for the difference in amplitude between the lower and upper supports that carry the high loads.
In case of earthquake
![]() | ![]() |
Seismic isolation device maintains stability even during seismic motion | The seismic isolation access floor maintains its load balance even during vibrations |
When applied to a rack-only seismic isolation device or to the seismic isolation access floor, our seismic isolation technology transmits energy to the top and isolates it to ensure the stability of both the seismic isolation device and the rack resting on the seismic isolation flooring.
Data Center Solutions
SP6000/P/K
SEISMIC ISOLATION RACK SP6000/P/K
SP-PRO
SEISMIC ISOLATION TABLESP-PRO
SP9000N/K
SEISMIC ISOLATION ACCESS FLOORSP9000N/K
Solutions for Data Center
Grating PanelSolutions for Data Center
Development Research Center
Quality assurance
Own research center and factory
Managed by a specialized team
Improved construction quality and direct on-site feedback
Many deliveries, both domestic & exports
Vietnam, China, Turkey, etc.
Head Office
Address : 46 Janggiteo 1-gil, Yangsan-si, Gyeongsangnamdo, S.Korea (Junam-dong)
Tel : 82-55-372-1775~7
Fax : 82-55-372-1779
Seoul Office
Address: #1505 Yuwon Golden Tower, 53 Chungjeong-ro, Seodaemun-gu, Seoul, S.Korea
Tel : 82-2- 312-1262~3
Fax : 82-2- 312-1268
EMEA & Turkiye Distributor Head Office
Address : Buyukdere Cad. Emlak Kredi Blokları A/2 Blok No: 3/36 No: 8 Levent–Istanbul-Türkiye
E-Mail: tunc.ertug@setekteknoloji.com
E-Mail: info@setekteknoloji.com
Tel : +90 212 318 32 50
Fax : +90 212 275 75 35
COPYRIGHT © 2023 Entire Safe Co., Ltd. All rights reserved.